Documents / Assemble Acetal Adaptor


Assemble the acetal adaptor

The adaptor foot valve can be fitted to the bottom of the cylinder to accommodate a submersible pump or extension pipes.

#1

Secure the cylinder

Secure the cylinder and remove the nuts and bolts.

#2

Fit the adaptor

Fit the Acetal adaptor in the opening.

#3

Tap adaptor in

Tap the adaptor in with a hammer and a piece of wood until the middle part of the adaptor is flush with the cylinder tube.

#4

Drill pilot holes

Take a 3.2mm drill bit and drill pilot holes 10mm deep into the adaptor.

#5

Insert self-tapping screws

Insert the self-tapping screws provided with the adaptor.