Documents / Assemble Adaptor Foot Valve


Assemble the adaptor foot valve

The adaptor foot valve can be fitted to the bottom of the cylinder to accommodate a submersible pump or extension pipes.

#1

Secure the cylinder

Secure the cylinder and remove the nuts and bolts.

#2

Remove foot valve

Very important! Remove the foot valve from the cylinder.

#3

Fit the adaptor

Fit the adaptor into the opening of the cylinder and tap the adaptor in with a hammer and a block of wood until the shoulder of the adaptor is flush with the bottom of the cylinder.

#4

Drill pilot holes

Drill 4mm pilot holes 12mm deep through the cylinder tube holes into the adaptor.

#5

Fasten self-tapping screws

Fasten the self-tapping screws provided with the adaptor.